Menu Items

These are the Menu Items for requesting data or changing device settings.

READ

Reading:

Selecting this item will tell the device to take a current pH reading. The reading will be displayed on the screen and updated in the app.

L-AL

Low Alarm:

Selecting this item will allow the user to set a value between 0 and 14 as a low alarm point. If the pH reading is below this setpoint the device will alarm.

H-AL

High Alarm:

Selecting this item will allow the user to set a value between 0 and 14 as a high alarm point. If the pH reading is above this setpoint the device will alarm.

TIME

Measurement Interval:

Selecting this item will allow the user to set a value between 1 minute and 60 minutes. The device automatically takes readings at this set time interval.

S-ST

Sensor State:

Selecting this item allows the user to put the device pH sensing to sleep or to wake it up. This setting is not saved between power cycle and will always be active when powered.

WAKE: Wakes the devices pH sensing.

SLEP: Puts the devices pH sensing to sleep.

C-LW

Low Point Calibration:

Selecting this item will start the automated Low Point Calibration process.

C-MI

Mid Point Calibration:

Selecting this item will start the automated Mid Point Calibration process.

C-HI

High Point Calibration:

Selecting this item will start the automated High Point Calibration process.

BRIT

Brightness:

Selecting this item will allow the user to set the devices display brightness.

LOW: Set the display brightness to the lowest brightness.

MED: Set the display brightness to the medium brightness.

HIGH: Set the display brightness to the highest brightness. This is the default setting.

SNUM

Device Serial Number:

Selecting this item will show you the assigned device serial number. It will show the first half for 5 seconds and then the second half for 5 seconds.

ALRM

Alarm:

This menu item allows the user to turn the audible alarm on and off.

ON: This enables the audible buzzer.

OFF: This disables the audible buzzer.

WIFI

Wi-Fi:

Selecting this item will allow the user to set the device online or offline.

CONN: Turn Wi-Fi on. This is the default setting.

DISC: Turn Wi-Fi off.

PreviousButton FunctionsNextWi-Fi/Cloud Connection Indicator